BJSPX - CARBON MONOXIDE IN AIR
- MSDS: BJSPX
- Manufacturer: NATIONAL DRAEGER INC
- Product Name: CARBON MONOXIDE IN AIR
- National Stock Number: 6830-00F013639
Product Identification
Product ID:CARBON MONOXIDE IN AIR
MSDS Date:01/04/1993
FSC:6830
NIIN:00F013639
MSDS Number: BJSPX
Responsible Party
PITTSBURGH, PA 15230
US
Emergency Phone: 412-787-8383/8389
Info Phone: 412-787-2207
Cage: 53833
Contractor
Telephone: 412-787-8383 OR 412-787-8389
Cage: 53833
Ingredients
CARBON MONOXIDE
CAS: 630-08-0
RTECS: FG3500000
OSHA PEL 50 PPM
ACGIH TLV: 25 PPM; 9293
COMPRESSED AIR
RTECS: AX5271000
Fraction By Weight: BALANCE
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CARBON MONOXIDE CAUSES OXYGEN
STARVATION OF BODY CELLS. CARDIOVASCULAR PROBLEMS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: HEADACHE, MENTAL DULLNESS,
DIZZINESS, POSSIBLE COLLAPSE & DEATH.
Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING STOPS, GIVE
ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS & FULL
PROTECTIVE CLOTHING. USE WATER SPRAY TO KEEP FIRE EXPOSED CYLINDERS
COOL.
Unusual Fire/Explosion Hazard:CONTAINER MAY RUPTURE UNDER FIRE
CONDITIONS. COMPRESSED AIR MAY ACCELERATE COMBUSTION.
Accidental Release
Spill Release Procedures:EVACUATE & VENTILATE AREA. REMOVE LEAKING
CYLINDER TO EXHAUST HOOD OR SAFE OUTDOORS AREA. ELIMINATE SOURCES
OF IGNITION.
Handling
Handling and Storage Precautions:STORE CYLINDERS IN A WELL VENTILATED
AREA. RETURN CYLINDERS WITH POSITIVE PRESSURE. DON'T DEFACE
CYLINDERS OR LABELS. AVOID TEMPS ABOVE 125F.
Other Precautions:MOVE CYLINDERS W/AN ADEQUATE HAND TRUCK. KEEP VALVE
PROTECTION CAP ON CYLINDERS WHEN NOT IN USE; SECURE DURING USE TO
PROTECT FROM FALLING. CYLINDERS MAY NOT BE REFILLED (VIOLATION OF
FEDERAL LAW).
Exposure Controls
Respiratory Protection:USE SELF-CONTAINED BREATHING APPARATUS IN CASE
OF EMERGENCY.
Ventilation:ADEQUATE GENERAL & LOCAL EXHAUST.
Eye Protection:SAFETY GLASSES OR GOGGLES
Supplemental Safety and Health
CONCENTRATION OF CARBON MONOXIDE IN PRODUCT IS 25-3000 PPM.
Chemical Properties
Vapor Density:1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
FLAMMABLE & COMBUSTIBLE MATERIALS, ESPECIALLY GREASES & OILS
Stability Condition to Avoid:HEAT, FLAMES. TEMPERATURES ABOVE 125F.
Disposal
Waste Disposal Methods:RETURN CYLINDERS TO SUPPLIER FOR PROPER DISPOSAL
W/ANY VALVE OUTLET PLUGS/CAPS SECURED & VALVE PROTECTION CAP IN
PLACE. ALLOW GAS TO DISCHARGE SLOWLY. WASTE CO CAN BE PIPED TO AN
APPROVED INCINERATOR TO BURN CO TO CO2 UNDER CONTROLLED
CONDITIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their